Comparison of model-predicted and measured moment arms for the rotator cuff muscles

Loading...
Thumbnail Image

Date

2007-07

Authors

Gatti, Christopher J.
Dickerson, Clark R.
Chadwick, Edward K.
Mell, Amy G.
Hughes, Richard E.

Advisor

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Abstract

Background The ability of mathematical models of the shoulder to accurately replicate physiological muscle moment arms is unknown. The purpose of this study was to compare model-predicted and experimentally measured moment arms for the rotator cuff muscles during arm elevation. Methods Moment arms obtained from six mathematical models and seven experimental studies were compared for the supraspinatus, infraspinatus, teres minor, and subscapularis for elevation in the scapular plane. Results All of the included models generated moment arms that generally fell within the range of experimentally measured data. Interpretation The quantitative agreement between model-predicted and experimentally measured moment arms supports the use of the included models for biomechanical shoulder analyses.

Description

The final publication is available at Elsevier via http://dx.doi.org/10.1016/j.clinbiomech.2007.02.001. © 2007. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/

Keywords

shoulder, moment arms, computational model

LC Subject Headings

Citation