Quantitative Comparison of Capture-SELEX, GO-SELEX, and Gold-SELEX for Enrichment of Aptamers

dc.contributor.authorDing, Yuzhe
dc.contributor.authorLiu, Juewen
dc.date.accessioned2025-09-11T20:44:16Z
dc.date.available2025-09-11T20:44:16Z
dc.date.issued2023-09-18
dc.descriptionThis document is the Accepted Manuscript version of a Published Work that appeared in final form in Analytical Chemistry, copyright © American Chemical Society after peer review and technical editing by publisher. To access the final edited and published work see https://doi.org/10.1021/acs.analchem.3c02477
dc.description.abstractSince 1990, numerous methods for aptamer selection have been developed, although a quantitative comparison of their sequence enrichment is lacking. In this study, we compared the enrichment factors of three library-immobilization SELEX methods (capture-SELEX, GO-SELEX, and gold-SELEX). We used a spiked library that contained multiple DNA aptamers with different affinities for adenosine. The aptamer separation efficiency was measured using qPCR, and all of the three methods showed a very low DNA release (<1%) in the presence of 100 μM adenosine. Among these, barely any DNA was released from the gold nanoparticles. Deep sequencing was used to compare the enrichment of three aptamers: Ade1301, Ade1304, and the classical aptamer. Enrichment up to 30 to 50-fold was observed only for the capture-SELEX method, whereas the other two methods showed enrichment factors below 1. By blocking the primer-binding regions of the library, GO-SELEX reached up to 14% enrichment. Finally, the enrichment of aptamers based on nonspecific release and target-induced release was discussed, and the advantages of capture-SELEX were rationalized. Taken together, these results indicate that capture-SELEX is a much more efficient method for enriching aptamers.
dc.identifier.urihttps://doi.org/10.1021/acs.analchem.3c02477
dc.identifier.uri10.1021/acs.analchem.3c02477
dc.identifier.urihttps://hdl.handle.net/10012/22398
dc.language.isoen
dc.publisherAmerican Chemical Society
dc.relation.ispartofseriesAnalytical Chemistry; 95(39)
dc.rightsAttribution-NonCommercial-ShareAlike 2.5 Canadaen
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/2.5/ca/
dc.titleQuantitative Comparison of Capture-SELEX, GO-SELEX, and Gold-SELEX for Enrichment of Aptamers
dc.typeArticle
dcterms.bibliographicCitationDing, Y., & Liu, J. (2023). Quantitative comparison of Capture-Selex, Go-Selex, and gold-selex for enrichment of aptamers. Analytical Chemistry, 95(39), 14651–14658. https://doi.org/10.1021/acs.analchem.3c02477
uws.contributor.affiliation1Faculty of Science
uws.contributor.affiliation2Chemistry
uws.peerReviewStatusReviewed
uws.scholarLevelFaculty
uws.typeOfResourceTexten

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Comparison of SELEX-11-revised3-clean.pdf
Size:
1.02 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
4.47 KB
Format:
Item-specific license agreed upon to submission
Description: