Quantitative Comparison of Capture-SELEX, GO-SELEX, and Gold-SELEX for Enrichment of Aptamers
dc.contributor.author | Ding, Yuzhe | |
dc.contributor.author | Liu, Juewen | |
dc.date.accessioned | 2025-09-11T20:44:16Z | |
dc.date.available | 2025-09-11T20:44:16Z | |
dc.date.issued | 2023-09-18 | |
dc.description | This document is the Accepted Manuscript version of a Published Work that appeared in final form in Analytical Chemistry, copyright © American Chemical Society after peer review and technical editing by publisher. To access the final edited and published work see https://doi.org/10.1021/acs.analchem.3c02477 | |
dc.description.abstract | Since 1990, numerous methods for aptamer selection have been developed, although a quantitative comparison of their sequence enrichment is lacking. In this study, we compared the enrichment factors of three library-immobilization SELEX methods (capture-SELEX, GO-SELEX, and gold-SELEX). We used a spiked library that contained multiple DNA aptamers with different affinities for adenosine. The aptamer separation efficiency was measured using qPCR, and all of the three methods showed a very low DNA release (<1%) in the presence of 100 μM adenosine. Among these, barely any DNA was released from the gold nanoparticles. Deep sequencing was used to compare the enrichment of three aptamers: Ade1301, Ade1304, and the classical aptamer. Enrichment up to 30 to 50-fold was observed only for the capture-SELEX method, whereas the other two methods showed enrichment factors below 1. By blocking the primer-binding regions of the library, GO-SELEX reached up to 14% enrichment. Finally, the enrichment of aptamers based on nonspecific release and target-induced release was discussed, and the advantages of capture-SELEX were rationalized. Taken together, these results indicate that capture-SELEX is a much more efficient method for enriching aptamers. | |
dc.identifier.uri | https://doi.org/10.1021/acs.analchem.3c02477 | |
dc.identifier.uri | 10.1021/acs.analchem.3c02477 | |
dc.identifier.uri | https://hdl.handle.net/10012/22398 | |
dc.language.iso | en | |
dc.publisher | American Chemical Society | |
dc.relation.ispartofseries | Analytical Chemistry; 95(39) | |
dc.rights | Attribution-NonCommercial-ShareAlike 2.5 Canada | en |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/2.5/ca/ | |
dc.title | Quantitative Comparison of Capture-SELEX, GO-SELEX, and Gold-SELEX for Enrichment of Aptamers | |
dc.type | Article | |
dcterms.bibliographicCitation | Ding, Y., & Liu, J. (2023). Quantitative comparison of Capture-Selex, Go-Selex, and gold-selex for enrichment of aptamers. Analytical Chemistry, 95(39), 14651–14658. https://doi.org/10.1021/acs.analchem.3c02477 | |
uws.contributor.affiliation1 | Faculty of Science | |
uws.contributor.affiliation2 | Chemistry | |
uws.peerReviewStatus | Reviewed | |
uws.scholarLevel | Faculty | |
uws.typeOfResource | Text | en |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Comparison of SELEX-11-revised3-clean.pdf
- Size:
- 1.02 MB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 4.47 KB
- Format:
- Item-specific license agreed upon to submission
- Description: